Air Handling Unit and Makeup Air Unit Replacements - AMIL & CALT

Active BPM059224 RFPConstruction - BuildingAnne Arundel Community College
The full text, documents and contacts of this bid open with a free account.Sign up free to read it

At a glance

Anne Arundel Community College (Maryland) posted this RFP on Oct 8, 2026. Responses are due Nov 11, 2026. Category: Construction - Building. Solicitation number BPM059224.

Solicitation details

General information

Solicitation number
BPM059224
Notice type
RFP
Place of performance
Maryland

Agency and category

Agency
Anne Arundel Community College
Category
005Construction - Building
Source listing
Link after sign-up

About this listing

ProposalWorkspace summary

This bid was found on the agency's procurement portal. The portal's own text is not republished here; the summary below was written by ProposalWorkspace's AI from the bid documents. The full posting is on the portal - sign up free to get the link.

Summary

AI-read from the bid documents

Summary fields on this page were extracted by AI from the bid documents. Always verify dates, amounts and requirements against the official solicitation.

What the bid is for

Anne Arundel Community College (AACC) is soliciting proposals from qualified Contractors to replace rooftop air handling units at the Arundel Mills Campus and a Makeup Air Unit at the Center for Applied Learning and Technology located on the Arnold Campus. The Work includes, but is not limited to, associated VAV repairs and modifications, integration with the existing Building Automation System (BAS), integration with the Fire Alarm System, testing, adjusting and balancing (TAB), required permits, and all related labor, materials, equipment, and services necessary to complete the Project.

Scope

Base Bid

- Remove RTU-4 and replace in-kind, modify fourth floor VAV terminals to be compatible with and operable from the existing BAS Tridium system.

Alternates (refer to pricing sheet for designations)

  • Remove RTU-1 and replace in-kind, modify lower level and first floor VAV terminals to be compatible with and operable from the existing BAS Tridium system.
  • Add reheat coils to existing VAVs without heating. Estimated quantity: Lower Level: 0; First Floor: 4; Second Floor: 5; Third Floor: 5; Fourth Floor: 0.
  • In lieu of repairing VAVs, replace existing VAVs with new units with reheat coils. Estimated quantity: Lower Level: 4; First Floor: 27; Second Floor: 0; Third Floor: 0; Fourth Floor: 19.

Additional information

PROVIDE TWO YEAR WARRANTY FOR ALL WORK (MATERIALS, LABOR, AND EQUIPMENT) FOR A PERIOD OF TWO YEARS COMMENCING WITH THE DATE OF ACCEPTANCE OF ALL WORK BY THE OWNER UNLESS OTHERWISE NOTED IN THE SPECIFICATIONS.

OBTAIN ALL LICENSES AND PERMITS REQUIRED BY STATE AND LOCAL JURISDICTIONAL AUTHORITIES FOR PERFORMANCE OF WORK.

Documents

9 files

Sign up free to get these 9 documents.

  • C2027-13-P_Addendum_2_10.30.26.pdf
    Download
  • C2027-13-P_Addendum_1_10.15.26.pdf
    Download
  • Appendix_C1_-_AMIL_RTU_Replacement_Phase_2.pdf
    Download
  • Appendix_D_-_TAB_Pre-Const_Deficiency_Report.pdf
    Download
  • Appendix_C2_-_CALT_MAU_Replacement.pdf
    Download
  • Appendix_B_-_Prevailing_Wage_Determination.pdf
    Download
  • C2027-13-P_AMIL-CALT_RTU-MAU_Replacements.pdf
    Download
  • Appendix_A_-_General_Terms_and_Conditions_of_Construction.pdf
    Download
  • Section_5.0_Project_References.xlsx
    Download

Similar open bids

In Maryland

More from Anne Arundel Community College

Open bids