ProposalWorkspaceFederal OpportunitiesDepartment of Veterans Affairs

Correct Electrical Deficiencies

Active 36C24627B0001 SolicitationService-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)Department of Veterans Affairs
The full text, documents and contacts of this bid open with a free account.Sign up free to read it

At a glance

246-Network Contracting Office 6 (36C246) of Department of Veterans Affairs posted this Solicitation on Nov 5, 2026. Responses are due Dec 8, 2026. NAICS 236220 (Commercial and Institutional Building Construction), product or service code 6150 (Miscellaneous Electric Power and Distribution Equipment). Set-aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14). Place of performance: North Carolina 28301. Solicitation number 36C24627B0001.

Solicitation details

General information

Solicitation number
36C24627B0001
Notice type
Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Place of performance
North Carolina 28301

Classification

NAICS
236220Commercial and Institutional Building Construction
Product or service
6150Miscellaneous Electric Power and Distribution Equipment

Agency

Department
Department of Veterans Affairs
Sub-tier
Department of Veterans Affairs
Office
246-Network Contracting Office 6 (36C246)

Description

From SAM.gov

SOW 
565-22-500 Correct Electrical Deficiencies 
Fayetteville VAMC

Intent
The project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements.  Period of performance 1,174 calendar days.
Medium Voltage
VA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope:
Replace existing medium voltage entrance equipment with new at campus entrance. 
Provide new building:
Slab on grade, brick on CMU wall, Slate roof tile (to match existing facility)
Provide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 .
Demo and remove old VA owned medium voltage entrance metal shack.
Replace medium voltage sectionalized switch. 
Provide new metal-clad switchgear with draw-out vacuum circuit breakers.
Replace medium voltage oil filled transformer (1)
Panel Replacement and Branch Circuit Improvements
Correct deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o 

All work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include:
Replace-in-same-room building entrance and large distribution equipment:
Normal (service entrance) Switchboards: approx. 2 
Generator switchboards: approx. 2 
Automatic transfer switch: approx. 7
Replace-in-place distribution panels and panelboards distribution equipment
Distribution Panels: approx. 5
Panelboards: approx. 68
Replace undersized feeders
Redundant Gound
Provide redundant equipment grounding conductor to a portion of the facility.
Approx. 100,000 square feet of existing electrical branch circuit distribution in occupied space. 
HVAC And Plumbing
Reroute (vertically & horizontally) Sewer piping and hot water piping to avoid electrical room.
Provide exhaust fan to new Medium Voltage building. 
Incidental Electrical Equipment Cleanup
Provide Identification tag to new and existing equipment throughout the facility: approx. 100 tags
Clean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures.
Correct panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels.

ALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.
 

Documents

4 files

Sign up free to download these 4 files.

  • 565-22-500 Combined Set 20251118.pdf
    41.6 MB
    Download
  • 36C24627B0001.docx
    271 KB · Nov 4, 2026
    Download
  • ATTACHMENT - BAA TAA COMPLIANCE CERTIFICATION.docx
    21 KB · Nov 4, 2026
    Download
  • Correct Electrical Deficiencies Specifications.pdf
    3.2 MB · Nov 4, 2026
    Download

Similar open bids

Same NAICS 236220

More from Department of Veterans Affairs

Open bids, other NAICS codes