Well 153 Vertical Turbine Pump Assembly

Active RFB 263-2026 IFBUtilities & EnergyRancho California Water District
The full text, documents and contacts of this bid open with a free account.Sign up free to read it

At a glance

Rancho California Water District (California) posted this IFB on Oct 25, 2026. Responses are due Nov 11, 2026. Category: Utilities & Energy. Solicitation number RFB 263-2026.

Solicitation details

General information

Solicitation number
RFB 263-2026
Notice type
IFB
Place of performance
California

Agency and category

Agency
Rancho California Water District
Category
018Utilities & Energy
Source listing
Link after sign-up

About this listing

ProposalWorkspace summary

This bid was found on the agency's procurement portal. The portal's own text is not republished here; the summary below was written by ProposalWorkspace's AI from the bid documents. The full posting is on the portal - sign up free to get the link.

Summary

AI-read from the bid documents

Summary fields on this page were extracted by AI from the bid documents. Always verify dates, amounts and requirements against the official solicitation.

What the bid is for

Rancho California Water District (“District”) is soliciting bids for the furnishing, assembly, and delivery of a new deep-set, water-lubricated vertical turbine pump assembly for the rehabilitation of Well 153. The purpose of this procurement is to restore pumping efficiency, production capacity, water quality, and operational reliability.

Scope

The Contractor shall furnish a complete, new, and fully assembled pump system, including the bowl assembly, column pipe, line-shaft assembly, bronze retainers with rubber bushings, intermediate and head shafts, sounding tubes, stainless steel suction screen and cone strainer, 125 HP vertical hollow-shaft motor, and all necessary hardware and materials. The District will furnish the fabricated steel discharge head and motor steady bushing.

The pump assembly shall achieve a design operating point of 2,000 gallons per minute (GPM) at 185 feet Total Dynamic Head (TDH), with a minimum pump efficiency of 83.6 percent. The operating duty point shall fall to the right of the pump's Best Efficiency Point (BEP). All equipment shall comply with the applicable material, coating, and NSF/ANSI 61 requirements identified in *Exhibit A*.

This solicitation is limited to equipment procurement and related technical support. District personnel or others under separate contract shall perform all installation, startup operations, testing, adjustments, and corrective fieldwork. The Contractor shall provide a qualified representative to observe initial startup, commissioning, and field performance testing, review operating conditions, document deficiencies, and provide technical recommendations.

Additional information

The Contractor shall remain responsible for equipment performance and applicable warranty obligations. Upon notification of an equipment deficiency, the Contractor shall respond within forty-eight (48) hours with technical assistance and coordination of replacement parts. When requested, the Contractor shall provide qualified personnel for onsite technical support within the same timeframe.

Factory hydraulic performance testing is not required. ANSI/HI 14.6.4, Grade 1B shall establish the District's hydraulic performance expectations, with the equipment required to meet the specified design-point conditions within ±5 percent. Final acceptance shall depend on satisfactory field performance verification and compliance with the Contract Documents.